CygNet Measurement > FMS Commands > Device Communication: Request New Data

Device Communication: Request New Data

Note: This command is supported for Nodes configured with FMS or FMS Legacy data groups. See EFM Data Items for more information.

Request New Data (REQNEWDATA via script) is a Node-level command that triggers the service to retrieve device data since the last successful poll. The type(s) of data requested is configurable via the command parameters. Available data is dependent on the configured device properties, which in turn is related to the types of data available in the associated field device. The types of data that can potentially come back are Periodic Metering (PM) history, Periodic Quality (PQ) history, Events history, Alarms history, Batch data, or Ticket data.

You can optionally configure the command to request the current configuration record on a less frequent specified interval, and/or to timeout if the request is not completed in a specified period of time. Additionally you can configure the command to also include missing data, or both unavailable and missing data, in the request.

Note: If the Request New Data command is configured to request data from a device that it does not support, the FMS service will recognize that, and the request will not be sent to the device in question. Only requested command results will be reflected in the Command Results field.

Devices are eligible if the following apply.

Note: Prior to the initial poll using this command, it is important that you first have current configuration data for the Node.

You must have proper security authorization to execute this command. See FMS Security (and CMDDEV security event) for information about configuring security access for FMS commands.

See Configuring Request New Data Commands and Running Node Commands for more information about using this command via FMS Explorer.

See Special FMS Command Notes for more information about requesting alarm and event data.

See Scheduling FMS Command Tasks in the MSS for more information about scheduling commands.

See FMS ActiveX Controls and CxHmiFms for more information about using commands via FMS ActiveX controls on CygNet Studio or CygNet Vision screens.

See CxFms for more information about scripting commands.

Command Definition Properties

The following command definition properties apply to Request New Data commands, when scheduling, creating, or editing commands via CygNet Explorer.

Property Description

FMS service

Select a Site.Service for the command from the available FMS service list in the drop-down menu.

Command

Select the desired Command name from the drop-down menu.

See FMS Commands for more information about available command types.

Time format

Select the desired Time format for the command from the drop-down menu.

Options are as follows.

  • Contract
  • Device

Default value is Device time.

Notes:

This parameter determines how the time window is selected in the database; not how the data is exported.

For daily devices only, specifying start and end times of midnight (00:00:00), will always be interpreted as Contract time format, regardless of this selected parameter value.

Priority

Select a processing queue Priority for the command from the drop-down menu.

Options from least to greatest priority are as follows.

  • Low level
  • Medium level
  • High level
  • User initiated transaction
  • Admin initiated transaction

Default value is Low level processing queue priority.

Logging

Select a Logging level for the command results from the drop-down menu.

Options are as follows.

  • Low - displays errors
  • Medium - displays errors and warnings
  • High - displays errors, warnings, and status

Default value is Low level logging when scheduling a command via the MSS service in CygNet Explorer.

Default value is High level logging when creating or running an ad-hoc command in FMS Explorer or via the FMS service in CygNet Explorer.

Command Parameters

The following command parameters apply to Request New Data commands, when scheduling, creating, or editing commands via CygNet Explorer or scripting.

Parameter Description Type Usage Notes

ClrTokens

Override data tokens with date/time

DateTime

Specifies the date/time to use to override the data tokens, in order to allow retrieval of data from a specific time. This may be necessary if the device loses power or is reset, resulting in the data tokens becoming invalid.

If used, double-click to access the Select Date/Time dialog box. See Note below this table.

See Selecting Date and Time for more information.

This parameter is optional.

CfgFreq

Configuration request frequency (days)

Integer

If used, double-click to access the Enter Configuration Request Frequency dialog box.

Type the request frequency into the text box.

This parameter is optional.

Timeout

Previous request timeout (hours)

Integer

If used, double-click to access the Enter Previous Request Timeout (Hours) dialog box.

Type the number of hours before which the request will timeout if it hasn't been completed by the UIS. Each device is only allowed a single outstanding poll (per type) at a time.

This parameter is optional.

GetGMHist

Get periodic metering history

String Enum

If used, double-click to access the Get Periodic Metering History dialog box.

Select one of the following options.

  • Yes (YES via script)
  • No (NO via script)

This parameter is optional. Default value is Yes.

GetGQHist

Get periodic quality history

String Enum

If used, double-click to access the Get Periodic Quality History dialog box.

Select one of the following options.

  • Yes (YES via script)
  • No (NO via script)

This parameter is optional. Default value is Yes.

GetEvents

Get events history

String Enum

If used, double-click to access the Get Events History dialog box.

Select one of the following options.

  • Yes (YES via script)
  • No (NO via script)

This parameter is optional. Default value is Yes.

See Special FMS Command Notes for more information about requesting alarm and event data.

GetAlarms

Get alarms history

String Enum

If used, double-click to access the Get Alarms History dialog box.

Select one of the following options.

  • Yes (YES via script)
  • No (NO via script)

This parameter is optional. Default value is Yes.

See Special FMS Command Notes for more information about requesting alarm and event data.

GetBatch

Get batch data

String Enum

If used, double-click to access the Get Batch Data dialog box.

Select one of the following options.

  • Yes (YES via script)
  • No (NO via script)

This parameter is optional. Default value is Yes.

GetTicket

Get ticket data

String Enum

If used, double-click to access the Get Ticket Data dialog box.

Select one of the following options.

  • Yes (YES via script)
  • No (NO via script)

This parameter is optional. Default value is Yes.

DataGaps

Request missing/unavailable data

String Enum

If used, double-click to access the Request Missing/Unavailable Data dialog box to include additional data in the request.

Select one of the following options.

  • Missing and unavailable data (All via script)
  • Missing data only (Missing via script)
  • None (None via script)

This parameter is optional. Default value is None.

Note: Date/time - When using relative (rather than absolute) date/time, if both the start and end date/time have hour, minute, and second values of 00 (or if both are set to midnight), an additional day will be added to the date at the end of the range. This occurs because the service assumes the start of the day for the starting date/time and the end of the day for the ending date/time in these circumstances. Therefore requesting a time range from T to T will yield one day of data, and from T-1 to T will yield two days of data. If only one day of data is desired when using relative date/time, the start and end date/times must therefore be the same. If any of the start or end date/time hour, minute, or second values are specified as a value other than zero (or midnight) however, the range will be used as specified.

Back to top

Let us know how we can improve this topic.